Scan-Speak Illuminator 15WU/4741T00
4Ω
Mid Bass
Nominal diameter | 6″ / 150 mm |
Resonance | 34 Hz |
Q factor | 0.23 |
Sensitivity | 86.8 dB |
Linear excursion | ± 9 mm |
Program Power | 150 W |
.jpg)
.jpg)
.jpg)
- Sensitivity (1W, 1m, infinite baffle) SPL1W 86.8dB
- Frequency response 34 - 5000Hz
Thiele & Small parameters
- Resonance frequency (free air) fS 34Hz
- Mechanical quality factor QMS 3.47
- Electrical quality factor QES 0.25
- Total quality factor QTS 0.23
Large signal parameters
- Maximum linear excursion xmax 9mm
- Maximum excursion before damage xlim 13mm
- Air volume displaced at xmax VD 83cm³
- Power handling P 80W
- Program power Pmax 150W
Voice Coil
- Nominal impedance Z 4Ω
- DC resistance RE 3.2Ω
- Inductance (1kHz, estimated) LE 0.39mH
- VC Diameter 42mm
- Winding height HVC 8mm
Magnet
- Force factor Bl 6N/A
- Motor constant Bl/√RE 3.35N/√W
- Air gap height HAG 20mm
- Material Neodymium
Diaphragm
- Effective diameter 108mm
- Effective area SD 92cm²
- Moving mass MMS 13g
- Moving mass (without air load) MMD 12.3g
- Material Paper sandwich
Suspensions
- Stiffness KMS 0.592N/mm
- Compliance CMS 1690µm/N
- Equivalent volume to the compliance VAS 20L
- Mechanical resistance RMS 0.8N·s/m
Dimensions
- Nominal diameter 6″
- 150mm
- Volume occupied by the driver 0.35L
- Net weight 1.7kg
.png)
.png)
Export this driver to a simulation software:
Closed Box Simulator·